NUE Power Block 36V 100AH
*Contact us to find out about our volume discounts for NGOs and distributors
Our 36V battery outshines the performance of lead acid batteries—allowing you to use almost all of the battery, not just 50%. And why de-rate a battery when temperatures exceed 77°F (25°C). Our batteries continue to work at full force over 122°F (50°C). Charge faster and more efficiently with the NUE 36V LiFePO4 Bluetooth Broadband Battery without the need to trickle charge like a lead acid battery. The low maintenance of LiFePO4 will make cleaning nuts, bolts and cables a thing of the past. This battery comes equipped with Modbus communications.
Advantages
PERFORMS AT 122 F/50 C
Operating in hot climates won’t prematurely kill the battery or cut its rating
PREVENTS THEFT
Unique application voltage prevents re-use
LONG-LASTING FORM FACTOR
Industrial lithium cells last 2-3X that of lead acid in non-broadband applications
NEAR-FULL ENERGY USAGE
Use at least 80% of the battery energy
BLUETOOTH & BASIC APPLICATION
Allows technicians to see the same comprehensive battery information as the NOC without opening the enclosure
HIGH CYCLE LIFE
Our battery cells are designed for over 5000 cycles
Why we use LiFeP04
We only use LiFePO4 cells from premium cell manufacturers to ensure the safest solutions for our customers. LiFePO4 is recognized by the solar industry as a safer solution than NMC (Nickel-Manganese-Cobalt) batteries used in electric vehicles. LiFePO4 also does not include cobalt.

Specifications
Electrical Performance | |
---|---|
Nominal Voltage | 38.4V |
Nominal Capacity | 100AH |
Energy Storage | 3840Wh |
Charge Cut Off Voltage | 43.8V |
Discharge Cut Off Voltage | 30.0V |
Self Discharge | < 1% / MONTH |
Cells | PRISMATIC CELLS |
Charge Performance | |
Recomended Charge Current | 20A |
Maximum Charge Current | 100A |
Recomended Charge Voltage | 43.8V |
Bms Charge Cut Off Voltage | 43.8V |
Reconnect Voltage | 42.6V |
Balancing Voltage | 42V |
Max Battery Parallel | 16 |
Discharge Performance | |
Max Cont. Discharge Current | 100A |
Peak Discharge Current | 200A |
Bms Discharge Cut Off Current | 250A |
Low Voltage Disconnect | 30V |
Bms Discharge Cut Off Voltage | 30V |
Reconnect Voltage | 31.2V |
Short Circuit Protection | 230uS — 500uS |
Mechanical Specs | |
Dimension (L X W X H) | 17.7” x 12.6” x 7.9” / 450 x 320 x 200mm |
Weight | 77lbs / 35 kg |
Terminal Type | M8 |
Terminal Torque | 150 in-lbs |
Case Material | METAL |
Enclosure Protection | IP65 |
Temperature Performance | |
Charge Temperature | 32ºF – 149ºF / 0 – 65ºC |
Discharge Temperature | -4ºF – +158ºF / -20 – +70ºC |
Storage Temperature | 41ºF – 95ºF / 5 – 35ºC |
Bms High Temperature Cut Off | 149ºF / 65ºC |
Reconnect Temperature | 131ºF / 55ºC |
Communications | |
Ports | RS-485 |
Protocol | RS-485 |
Dry Contacts | 4 |
Bms Integrated | BUILT IN |
Operation Temperature | -40ºF – +185ºF / -40 – +85ºC |
Compliance | |
Certifications | CE, UN38.3, UL1642 & IEC62133 |
Shipping Clasification | UN3480, CLASS 9 |